I/O-Modules. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
 | ENCODER MODULE. |
|
|
|
|
The module uses two signal inputs for connection of an encoder with 24V signal amplitude and 90° phase position between signal A and B. The pulse edges at the input are counted.
The counter has a width of 32 bit and counts up or down according to turning direction. On request from RS485, the actual value is transmitted.
|
 |
ZOOM. |
|
|
| TECHNISCHE DATEN. |
 |
|
| Inputs/outputs | Pulse A / B and RS485 |
| Plugs | Weidmann-plugs 4-pin and 8-pin |
| Power supply | 18 - 30 V DC, < 250 mA |
| Ambient conditions | 0 - 40° C, 35 - 85 % rel. humidity, non-condensing |
| Dimensions | 168 mm × 39 mm × 109 mm |
| Weight | ca. 200 g |
| Enclosure rating | IP 20 |
| |
|
|
|
 | SSI ENCODER MODULE. |
|
|
|
|
Absolute value encoders can be adapted to LAP SynchroNet by using the SSI Encoder Module. The module is equipped with 2 data and 2 clock inputs, each for positive and inverted signals.
On request from RS485, the actual value is transmitted in a width of 32 bits.
|
 |
ZOOM. |
|
|
| TECHNICAL DATA. |
 |
|
| Inputs/outputs | RS485 and Clock+, Clock-, Data+, Data- |
| Plugs | Weidmann-plugs 4-pin and 8-pin |
| Power supply | 18 - 30 V DC, < 250 mA |
| Ambient conditions | 0 - 40° C, 35 - 85 % rel. humidity, non-condensing |
| Dimensions | 50 mm × 90 mm × 60 mm |
| Weight | ca. 250 g |
| Enclosure rating | IP 20 |
| |
|
|
|
|
|