患者标记

 

激光器技术 - 患者与机器之间的精确界面

精密、准确、可重现的患者定位功能是放射治疗的成功典范。虚拟仿真是将放射治疗方案从静态 3D 患者模型传送到正在进行治疗的患者身上的过程。虚拟仿真不仅是在患者身上标记坐标的过程,还是确保放射治疗质量的基本步骤。会在虚拟仿真过程中检查放射治疗方案的有效性,并确保治疗光束可与计划目标体积校准。定位和标记激光器是患者与机器之间的连接界面。LAP 激光器可实现最高的准确性、精确性和可重现性,为放射治疗提供了可靠的基础。

Please find here our moving laser systems for CTMR and laser control systems for patient alignment.

Laser systems for patient marking at ct + pet/ct

APOLLO laser bridge for CT + PET/CT
Customized bridge
Customized bridge

APOLLO

Projected body planes:
Sagittal, transversal, coronal planes:
Three fixed crosshair lasers from the top and the sides
Shifting is possible by moving the patient table

Laser adjustment:
Remote controlled

Laser color:
Red, Green or Blue

Mounting option:
Customized bridge

Laser control:
No

Quality assurance:
WILKE phantom

Room planning within pre-installation service:
Yes

DORADO 1 laser system for CT + PET/CT

Mounting options

wall-ceiling-wall
post-ceiling-post
post-ceiling-wall
wall-ceiling-post
Customized bridge
Customized bridge
 
 
 

DORADO 1

Projected body planes:
Sagittal:
One movable laser line from the ceiling rail

Transversal, Coronal:
One fixed laser line from the ceiling rail and one fixed crosshair laser line from each side
Shifting is possible by moving the patient table

Laser adjustment:
Manually

Laser color:
Red

Mounting option:
Wall, Post, Customized bridge

Laser control:
CARINAnav

Quality assurance:
WILKE phantom

Room planning within pre-installation service:
Yes

DORADO 3 laser system for CT + PET/CT

Mounting options

wall-ceiling-wall
post-ceiling-post
post-ceiling-wall
wall-ceiling-post
Customized bridge
Customized bridge
 
 
 

DORADO 3

Projected body planes:
Sagittal:
One movable laser line from the ceiling rail

Transversal:
One fixed laser line from the ceiling rail and one fixed laser line from each wall/post rail
Shifting is possible by moving the patient table

Coronal:
Two movable laser lines, each from the wall/post rails

Laser adjustment:
Manually

Laser color:
Red

Mounting option:
Wall, Post, Customized bridge

Laser control:
CARINAnav

Quality assurance:
WILKE phantom

Room planning within pre-installation service:
Yes

DORADOnova 1 laser system for CT + PET/CT

Mounting options

wall-ceiling-wall
post-ceiling-post
post-ceiling-wall
wall-ceiling-post
Customized bridge
Customized bridge
 
 
 

DORADOnova 1

Projected body planes:
Sagittal:
One movable laser line from the ceiling rail

Transversal, Coronal:
One fixed laser line from the ceiling rail and one fixed crosshair laser line from each side
Shifting is possible by moving the patient table

Laser adjustment:
Remote controlled

Laser color:
Red, Green, Blue

Mounting option:
Wall, Post, Customized bridge

Laser control:
CARINAnav

Quality assurance:
WILKE phantom

Room planning within pre-installation service:
Yes

DORADOnova 3 laser system for CT + PET/CT

Mounting options

wall-ceiling-wall
post-ceiling-post
post-ceiling-wall
wall-ceiling-post
Customized bridge
Customized bridge
 
 
 

DORADOnova 3

Projected body planes:
Sagittal:
One movable laser line from the ceiling rail

Transversal:
One fixed laser line from the ceiling rail and one fixed laser line from each wall/post rail
Shifting is possible by moving the patient table

Coronal:
Two movable laser lines, each from the wall/post rails

Laser adjustment:
Remote controlled

Laser color:
Red, Green, Blue

Mounting option:
Wall, Post, Customized bridge

Laser control:
CARINAnav

Quality assurance:
WILKE phantom

Room planning within pre-installation service:
Yes

DORADOnova 5 laser system for CT + PET/CT

Mounting options

wall-ceiling-wall
post-ceiling-post
post-ceiling-wall
wall-ceiling-post

DORADOnova 5

Projected body planes:
Sagittal:
One movable laser line from one ceiling rail

Transversal:
Two movable laser lines from two ceiling rails

Coronal:
Two movable laser lines, each from the wall/post rails

Laser adjustment:
Remote controlled

Laser color:
Red, Green, Blue

Mounting option:
Wall, Post, Customized bridge

Laser control:
CARINAnav

Quality assurance:
WILKE phantom

Room planning within pre-installation service:
Yes

Laser systems for patient marking at mrt

APOLLO MR3T laser bridge for MRT
Customized bridge
Customized bridge

APOLLO MR3T

Projected body planes:
Sagittal, transversal, coronal planes:
Three fixed crosshair lasers from the top and the sides
Shifting is possible by moving the patient table

Laser adjustment:
Remote controlled

Laser color:
Red, Green or Blue

Mounting option:
Customized bridge

Laser control:
No

Quality assurance:
AQUARIUS phantom (optional)

Room planning within pre-installation service:
Yes

DORADOnova MR3T laser bridge for MRT
Customized bridge
Customized bridge mounting

DORADOnova MR3T

Projected body planes:
Sagittal:
One movable laser line from the top

Transversal:
One fixed laser line from the top and one fixed laser line from each side
Shifting is possible by moving the patient table

Coronal:
One movable laser line from each side

Laser adjustment:
Remote controlled

Laser color:
Red, Green, Blue

Mounting option:
Customized bridge

Laser control:
CARINAnav

Quality assurance:
AQUARIUS phantom (optional)

Room planning within pre-installation service:
Yes